Mge Ups Pulsar Evolution 800 Manual

View and Download MGE UPS Systems 800 Tower instruction manual online. Atria Menu Nutritional Information. MGE UPS SYSTEMS pays great attention. The Pulsar Evolution UPS is intended for. Manual Pulsar Evolution Ups 1500 Installation and user. MGE UPS SYSTEMS. Pulsar Evolution. 1500 Tower/1500 Rack. 1100 Tower/1100 Rack.

Mge Ups Pulsar Evolution 800 Manual

MGE UPS Systems 1660 Scenic Avenue Costa Mesa, CA 92626 (714) 557-1636 For service call 1-800-438-7373 www.mgeups.com IMPORTANT SAFETY INSTRUCTIONS Read before installing product SAVE THESE INSTRUCTIONS. This manual contains important instructions for 6that should be followed during installation and maintenance of the UPS and batteries. Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar Evolution range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products.

Measures that have made Pulsar Evolution a reference in environmental protection include: The eco-designapproach used in product development, recycling of Pulsar Evolution at the end of its service life. To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar Evolution range, we invite you to visit our web site at www.mgeups.com or contact your MGE UPS SYSTEMS representative. This manual contains important instructions for Pulsar Evolution Models that must be followed during installation, operation and maintenance of the UPS and batteries. The Pulsar Evolution UPS Models that are covered in this manual are listed below. Pulsar Evolution 500, 800, 1100, 1500 The normal battery voltage for all models is as follows: Pulsar Evolution 500-12V, 800-24V, 1100-24V, 1500-36V The Pulsar Evolution UPS is intended for installation in a temperature within 0 to 35º C (Pulsar Evolution from 500 to 1100 VA) or within 0 - 40º C for Pulsar Evolution 1500, free of conductive contaminants. Note This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Introduction CAUTION: Safety of persons The UPS has its own internal power source (the battery).

Consequently, the power outlets may be energized even if the UPS is disconnected from the AC-powersource. Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. The UPS must be properly earthed. Measurements are required to ensure that the total leakage current of the UPS and the protected equipment does not exceed 3.5 mA by checking their characteristics (maximum leakage current of the UPS = 2 mA). The battery supplied with the UPS contains small amounts of toxic materials.

To avoid accidents, the directives listed below must be observed: - Never burn the battery (risk of explosion). - Do not attempt to open the battery (the electrolyte is dangerous for the eyes and skin). - Comply with all applicable regulations for the disposal of the battery. - Batteries constitute a danger (electrical shock, burns). The short-circuitcurrent may be very high. Precautions must be taken for all handling: remove watches, rings, bracelets and any other metal objects, use tools with insulated handles.

- Do not lay tools or metal parts on top of batteries. CAUTION: Product safety The UPS connection instructions and operation described in the manual must be followed in the indicated order. Brenda Russell Kiss Me With The Wind Rapidshare Programs.

UPS must be connected to a nearby wall outlet that is easily accessible. The UPS can be disconnected from the AC-powersource by removing the power cord. Check that the indications on the rating plate correspond to your AC-powersystem and to the actual electrical consumption of all the equipment to be connected to the UPS.

Never install the UPS near liquids or in an excessively damp environment. Never let a foreign body penetrate inside the UPS. Never block the ventilation grates of the UPS. Never expose the UPS to direct sunlight or source of heat. If the UPS must be stored prior to installation, storage must be in a dry place.

The admissible storage temperature range is -25ºCto +55ºC. Special precautions All handling operations will require at least two people (unpacking, installation in rack system). Once installed and connected to the AC power source for the first time, the battery will start to charge. Full charging to obtain the rated battery backup time requires at least 8 hours. Before and after the installation, if the UPS remains de-energizedfor a long period, the UPS must be energized for a period of 24 hours, at least once every 6 months (for a normal storage temperature less than 25°C). This charges the battery, thus avoiding possible irreversible damage. During the replacement of the battery module, it is imperative to use the same type and number of element previously mounted in the UPS, in order to maintain an identical level of performance and safety.